Project

General

Profile

Wiki » History » Version 91

Frédéric Blanc, 2024-07-16 14:59

1 1 Frédéric Blanc
h1. Wiki
2
3 42 Frédéric Blanc
!{width: 30%}https://redmine.laas.fr/attachments/download/4815/Face%20AV%20PS.jpg!
4 43 Frédéric Blanc
5 42 Frédéric Blanc
!{width: 30%}https://redmine.laas.fr/attachments/download/4814/Face%20AR%20PS.jpg!
6
7 41 Frédéric Blanc
{{toc}}
8
9 11 Frédéric Blanc
h2. Modbus / RS485 isolated
10
11 25 Frédéric Blanc
!clipboard-202404091540-4btca.png!
12
13 50 Frédéric Blanc
https://arduino103.blogspot.com/2021/10/decoder-une-trame-rs485-loscilloscope.html
14
15 25 Frédéric Blanc
h3. non isoler
16 24 Frédéric Blanc
17
!clipboard-202404091414-fugem.png!
18
19 21 Frédéric Blanc
!clipboard-202404081517-wbjgq.png!
20
21 27 Frédéric Blanc
h4. Fusibles réarmables
22
23
!clipboard-202404091611-8b8z9.png!
24
25 23 Frédéric Blanc
h3. Texas Instruments ISOW14x2 Isolated RS-485 DC-DC Converter
26 22 Frédéric Blanc
27
!clipboard-202404081533-dzk67.png!
28
29 18 Frédéric Blanc
h3.  ANALOG DEVICES LTM2881CV-5#PBF
30
31 19 Frédéric Blanc
!clipboard-202404051942-kmfn5.jpg!
32
33 18 Frédéric Blanc
Transceiver, RS422, RS485, 20 Mbps, 1 Driver, 1 Récepteur, 4,5 à 5.5V, 0 à 70°C, LGA-32
34
35
Code Farnell 4023829
36
37
h3. ADM2865E Power Isolated, RS-485 Transceivers
38 12 Frédéric Blanc
39 1 Frédéric Blanc
!clipboard-202404041435-zyzea.png!
40 12 Frédéric Blanc
41 13 Frédéric Blanc
|Code Farnell|Référence Fabricant	|Fabricant / Description|
42 12 Frédéric Blanc
|4023816	|ADM2865EBRNZ	|ANALOG DEVICES  Transceiver, RS422, RS485, 25 Mbps, 1 Driver, 1 Récepteur, 3 à 5.5V, -40 à 105°C, WSOIC-28|
43
|1456395	|SM712.TCT	|SEMTECH  Diode TVS, SM, Bidirectionelle, 12 V, 26 V, SOT-23, 3 Broche(s)|
44
|1515786	|BLM15HD182SN1D	|MURATA  Perle de ferrite, 0402 [1005 Metric], 1.8 kohm, 200 mA, BLM15H, 2.2 ohm, ± 25%|
45
|1867958	|08053D106KAT2A	|KYOCERA AVX  Condensateur céramique multicouche CMS, 10 µF, 25 V, 0805 [Métrique 2012], ± 10%, X5R|
46
|2443238	|BLM18HE601SN1D	|MURATA  Perle de ferrite, 0603 [1608 Metric], 600 ohm, 800 mA, BLM18H, 0.25 ohm, ± 25%|
47 11 Frédéric Blanc
48 37 Frédéric Blanc
h3. Module de communication d'isolation, ADUM3201 + B0505XT TTL à RS485
49
50
!clipboard-202404231543-s8vft.png!
51
52
*Attention RX sur TX*
53
54 83 Frédéric Blanc
h3. DFR0845 
55
56
!clipboard-202407041533-yroi0.png!
57 90 Frédéric Blanc
!clipboard-202407121501-bz7ns.png!
58 83 Frédéric Blanc
Ce module de transfert de signal RS485 vers UART actif et isolé est livré avec des circuits de protection tels que l'isolation de puissance et le TVS. Compatible avec la plupart des contrôleurs principaux, il présente les caractéristiques d'une vitesse de communication rapide, de performances stables et fiables, d'une sécurité élevée, etc., et peut être appliqué à divers capteurs industriels, équipements de contrôle industriel ou applications nécessitant une conversion de signal RS485.
59
https://wiki.dfrobot.com/Gravity_Active_Isolated_RS485_to_UART_Signal_Converter_SKU_DFR0845
60
61 84 Frédéric Blanc
 N° Mouser :
62
426-DFR0845 
63
www.gotronic.fr
64 85 Frédéric Blanc
Code: 37411
65
https://fr.farnell.com
66 1 Frédéric Blanc
Code Commande :
67 88 Frédéric Blanc
3974134
68 84 Frédéric Blanc
69 28 Frédéric Blanc
h3. RS485 I2C
70
71
!clipboard-202404120929-wdgmq.png!
72
73 20 Frédéric Blanc
h2. XY5005E
74
75 40 Frédéric Blanc
com le port 4 broches JST 1.25 ne semble pas avoir de TX, ni de RX. Il n'y a pas non plus de menu pour le chois de l'adressage
76 20 Frédéric Blanc
77
!clipboard-202404081443-iygma.png!
78 39 Frédéric Blanc
!clipboard-202404241236-ulutn.png!
79 38 Frédéric Blanc
!clipboard-202404241234-m5crk.png!
80
81 14 Frédéric Blanc
h2. XY6015L Step-Down Regulated Power Supply
82 1 Frédéric Blanc
83
!clipboard-202403251011-lfrn1.png!
84
85 4 Frédéric Blanc
µC AT32F421  ARM® Cortex®-M4 core
86
Ctrl EG1163S BUCK DC-DC de Rectification synchrone 300kHz
87
MOS NCE82H140
88
89 81 Frédéric Blanc
h2. DPS5005
90
91
!clipboard-202406181357-wvt60.png!
92
93
94
95
Module d'alimentation à afficheur LCD réglable en tension de 0 à 50 Vcc et en intensité de 0 à 5 A. L'écran couleur de 1,44'' offre un affichage particulièrement détaillé et complet des informations.
96
97
https://www.gotronic.fr/art-alimentation-programmable-dps5005-29294.htm
98
99 86 Frédéric Blanc
h3. modification port com
100
101
La vitesse de communication par défaut du port série DPS5005 est de 9 600 bauds, mais vous pouvez la modifier en alimentant l'alimentation tout en maintenant le bouton V/M1 enfoncé. Lorsque la modification est effectuée, appuyez deux fois sur le bouton « set » pour enregistrer la nouvelle configuration.
102
103 91 Frédéric Blanc
h3. Firmware alternatif
104
105
https://github.com/kanflo/opendps
106
107 87 Frédéric Blanc
h3. Brochage port com
108
109
!clipboard-202407121448-7reos.png!
110
111
112 81 Frédéric Blanc
h2. DPH5005
113
114
!clipboard-202406181358-4or4r.png!
115
116
Module d'alimentation à afficheur LCD 1,44" réglable en tension de 0 à 50 Vcc et en intensité de 0 à 5 A. Ce module délivre un signal de sortie haute résolution réglable par paliers de 10 mV et de 1 mA.
117
118
https://www.gotronic.fr/art-alimentation-programmable-dph5005-31537.htm
119
120 31 Frédéric Blanc
h3. Modbus
121
122 1 Frédéric Blanc
!clipboard-202404121322-qk0l1.png!
123 32 Frédéric Blanc
124 53 Frédéric Blanc
voir documentation document:"protocol -english translation V1.2"
125
126 64 Frédéric Blanc
|_.function code|_.Definition|_.Operation (binary)|
127 52 Frédéric Blanc
|0x03|Read register data|Read data from one or more registers|
128
|0x06|Write a single register|Write a set of binary data to a single register|
129
|0x10|Write multiple registers|Write multiple sets of binary data to multiple registers|
130
131 61 Frédéric Blanc
|\5=. *0x03 Read the function of the host format* |
132 57 Frédéric Blanc
|address code|function code|Register start address |Number of register
133
 addresses n (1 ~ 32)|CRC Check code|
134 54 Frédéric Blanc
|1 byte|1 byte|2 byte|2 byte|2 byte|
135
136 62 Frédéric Blanc
|\5=. *0x03 Read function Slave returns format*|
137
|address code|function code|Returns the number of bytes 2 * n|Register data|CRC Check code|
138
|1 byte|1 byte|1 byte|2*n Bytes|2 byte|
139 52 Frédéric Blanc
140 63 Frédéric Blanc
|\5=. *0x06 Write a single register function in host format*|
141
|address code|function code|Register address|Register data|CRC Check code|
142 1 Frédéric Blanc
|1 byte|1 byte|2 byte|2 byte|2 byte|
143 64 Frédéric Blanc
144 65 Frédéric Blanc
|\5=. *0x06 Write a single register function from the machine to return the format*|
145 64 Frédéric Blanc
|address code|function code|Register address|Register data|CRC Check code|
146
|1 byte|1 byte|2 byte|2 byte|2 byte|
147
148 68 Frédéric Blanc
|\6=. *0x10 Write function host format*|
149 67 Frédéric Blanc
|address code|function code|Register start address|Number of register addresses
150
n (1 ~ 32)|Write the number of bytes 2 * n|Register data|CRC Check code|
151 66 Frédéric Blanc
|1 byte|1 byte|2 byte|2 byte|1 byte|2*n byte|2 byte|
152
153
|\5=. *0x10 Write function slave return format*|
154 67 Frédéric Blanc
|address code|function code|Register start address|Number of register addresses
155 66 Frédéric Blanc
n (1 ~ 32)|CRC Check code|
156
|1 byte|1 byte|2 byte|2 byte|2 byte|
157 63 Frédéric Blanc
158 69 Frédéric Blanc
Protocol register description (single register address data for double-byte data)
159 70 Frédéric Blanc
160 76 Frédéric Blanc
|name|Description|number of bytes|Decimal point|unit|Read and write|Register address|dps_modbus.py|
161
|U-SET|Voltage setting|2|2|V|R/W|0x0000|voltage_set|
162
|I-SET|Current setting|2|2|A|R/W|0x0001|current_set|
163
|UOUT|Output voltage display value|2|2|V|R|0x0002|voltage|
164
|IOUT|Output current display value|2|2|A|R|0x0003|current|
165
|POWER|Output power display value|2|2|W|R|0x0004|power|
166
|UIN|Input voltage display value|2|2|V|R|0x0005|voltage_in|
167
|LOCK|Key lock|2|0|-|R/W|0x0006|lock|
168
|PROTECT|Protection state|2|0|-|R|0x0007|protect|
169
|CVCC|Constant voltage constant current state|2|0|-|R|0x0008|cv_cc|
170
|ONOFF|Switch output|2|0|-|R/W|0x0009|onoff|
171
|B_LED|Backlight brightness level|2|0|-|R/W|0x000A|b_led|
172
|MODEL|Product number|2|0|-|R|0x000B|model|
173
|VERSON|Firmware version number|2|0|-|R|0x000C|version|
174
|EXTRACT_M|Quickly bring up data sets|2|0|-|W|0x0023|extract_m|
175
|U-SET|Voltage setting|2|2|V|R/W|0x0050|voltage_set2|
176
|I-SET|Current setting|2|3|A|R/W|0x0051|current_set2|
177
|S-OVP|Overvoltage protection|2|2|V|R/W|0x0052|s_ovp|
178
|S-OCP|Overcurrent protection value|2|3|A|R/W|0x0053|s_ocp|
179
|S-OPP|Over power protection value|2|1、2|W|R/W|0x0054|s_opp|
180
|B-LED|Backlight brightness level|2|0|-|R/W|0x0055|b_led2|
181
|M-PRE|The data is called to update the output|2|0|-|R/W|0x0056|m_pre|
182
|S-INI|Power on the output switch|2|2|-|R/W|0x0057|s_ini|
183 75 Frédéric Blanc
184 76 Frédéric Blanc
h3. dps_modbus.py
185 69 Frédéric Blanc
186 79 Frédéric Blanc
|commande|Description|
187 78 Frédéric Blanc
|voltage_set|Voltage setting|
188
|current_set|Current setting|
189
|voltage|Output voltage display value|
190
|current|Output current display value|
191
|power|Output power display value|
192
|voltage_in|Input voltage display value|
193
|lock|Key lock|
194
|protect|Protection state|
195
|cv_cc|Constant voltage constant current state|
196
|onoff|Switch output|
197
|b_led|Backlight brightness level|
198
|model|Product number|
199
|version|Firmware version number|
200
|extract_m|Quickly bring up data sets|
201
|voltage_set2|Voltage setting|
202
|current_set2|Current setting|
203
|s_ovp|Overvoltage protection|
204
|s_ocp|Overcurrent protection value|
205
|s_opp|Over power protection value|
206
|b_led2|Backlight brightness level|
207
|m_pre|The data is called to update the output|
208
|s_ini|Power on the output switch|
209 77 Frédéric Blanc
|read_all|Read data as a block, much faster than individual reads|
210
|write_voltage_current|write voltage & current as a block|
211
|write_all|write block|
212
213
214 47 Frédéric Blanc
/dev/ttyACM0 ou /dev/ttyUSB0
215 32 Frédéric Blanc
baud rate *115200*
216 31 Frédéric Blanc
217 1 Frédéric Blanc
Slave Address: 1..247 ( *0: broadcast* )
218 31 Frédéric Blanc
Function code: see later
219
Data: 0..252 byte(s)
220 33 Frédéric Blanc
*CRC16-MODBUS* : see https://crccalc.com/ for code.
221 48 Frédéric Blanc
https://github.com/LacobusVentura/MODBUS-CRC16
222 31 Frédéric Blanc
223 1 Frédéric Blanc
224 34 Frédéric Blanc
h3. test commande
225
226 1 Frédéric Blanc
227 46 Frédéric Blanc
228 45 Frédéric Blanc
sur /dev/ttyACM0
229 1 Frédéric Blanc
230 46 Frédéric Blanc
Broadcast Power ON
231 1 Frédéric Blanc
<pre><code class="shell">
232 35 Frédéric Blanc
echo -ne "\x00\x06\x00\x12\x00\x01\xE9\xDE" > /dev/ttyACM0
233 34 Frédéric Blanc
</code></pre>
234
235 36 Frédéric Blanc
Broadcast Power OFF
236
<pre><code class="shell">
237
echo -ne "\x00\x06\x00\x12\x00\x00\x28\x1E" > /dev/ttyACM0
238
</code></pre>
239 1 Frédéric Blanc
240 45 Frédéric Blanc
sur /dev/ttyUSB0
241 1 Frédéric Blanc
242 46 Frédéric Blanc
Broadcast Power ON
243 45 Frédéric Blanc
<pre><code class="shell">
244
echo -ne "\x00\x06\x00\x12\x00\x01\xE9\xDE" > /dev/ttyUSB0
245
</code></pre>
246
247
Broadcast Power OFF
248
<pre><code class="shell">
249
echo -ne "\x00\x06\x00\x12\x00\x00\x28\x1E" > /dev/ttyUSB0
250
</code></pre>
251 36 Frédéric Blanc
252 30 Frédéric Blanc
h3. notice
253 15 Frédéric Blanc
254
presser [SW] pendant 2s pour accéder aux paramètres 
255
!clipboard-202404041503-e5ifh.png!
256
257 6 Frédéric Blanc
h2. GUI Python
258
259 9 Frédéric Blanc
h3. venv — Création d'environnements virtuels
260 6 Frédéric Blanc
261
<pre><code class="shell">
262 8 Frédéric Blanc
$ python3 -m venv venv
263 6 Frédéric Blanc
</code></pre>
264
265
Pour activer l'environnement, exécutez
266
267
<pre><code class="shell">
268
source venv/bin/activate
269
</code></pre>
270
271 7 Frédéric Blanc
<pre><code class="shell">
272
. venv/bin/activate
273
</code></pre>
274
275 51 Frédéric Blanc
sous Windows
276
<pre><code class="shell">
277
env\Scripts\activate.bat
278
</code></pre>
279
280 9 Frédéric Blanc
Vous devrez « quitter » ou « désactiver » votre environnement virtuel à l'aide de la commande 
281 6 Frédéric Blanc
282
<pre><code class="shell">
283
deactivate
284
</code></pre>
285
286
287
288 1 Frédéric Blanc
https://docs.python.org/fr/3/library/venv.html
289
290 16 Frédéric Blanc
h3. pyqt5
291
292
<pre><code class="shell">
293
pip3 install pyqt5 --config-settings --confirm-license= --verbose
294
</code></pre>
295
296 17 Frédéric Blanc
https://stackoverflow.com/questions/73714829/pip-install-pyqt5-it-cannot-go-on
297 16 Frédéric Blanc
298 9 Frédéric Blanc
h3. XY6015L_pyGUI
299
300 44 Frédéric Blanc
lancement de l'interface
301
302
<pre><code class="python">
303
python dps_GUI_program.py
304
</code></pre>
305
306 9 Frédéric Blanc
!clipboard-202404041117-w53xm.png!
307
308
configuration du port com
309
310
le port série peut être corrigé en modifiant le paramètre "port_set" dans "dps5005_limits.ini".
311
312
313
<pre><code class="shell">
314
[SectionZero]
315
The parameters below limit the code from incorrectly transmitting extreme values entered by the user:
316
if threshold exceeded value defaults to zero:
317
This file may be adapted for other versions of 'DPSxxxx' power supplies:
318
319
[SectionOne]
320
#leave empty "" for automatic port scanning or set serial port e.g. "/dev/cu.wchusbserial1410" or "/dev/ttyUSB0":
321
port_set: "/dev/ttyACM0"	#
322
323
#The parameters below limit the code from incorrectly transmitting extreme values entered by the user:
324 1 Frédéric Blanc
#if threshold exceeded value defaults to zero:
325 10 Frédéric Blanc
...
326 9 Frédéric Blanc
</code></pre>
327
328
h2. Sources
329 5 Frédéric Blanc
330 82 Frédéric Blanc
https://profimaxblog.ru/dps_update/
331 26 Frédéric Blanc
https://www.circuitstate.com/tutorials/what-is-rs-485-how-to-use-max485-with-arduino-for-reliable-long-distance-serial-communication/
332 29 Frédéric Blanc
http://xj900diversion.free.fr/bus/I2C%20-%20RS-485%20adapter.htm
333 5 Frédéric Blanc
https://github.com/AntaresAdroit/RDTech_PS_Comm
334
https://github.com/lambcutlet/DPS5005_pyGUI
335
https://github.com/kbs3056/XY6015L_pyGUI